Anmol Chemicals is the pioneer manufacturers of Propionic Acid, Pharmaceutical Excipients Food & Flavor chemicals in India. We offer Halal and Kosher Propionic Acid made in an ISO9001, ISO22000 (FSSC22000) and cGMP certified facility. Our group has several manufacturing facilities spread across the world, supported by toll manufacturers and representatives in UAE, Europe, USA, China and has several associated manufacturing facilities spread across India. All the Information on Physics, Chemistry, Applications, Uses and Technology on Manufacture of Propionic Acid is in these pages.
The units have one or more of the certifications like FDA GMP, ISO 9001, ISO 22000, HACCP, REACH, Kosher & Halal

Home ------------ Contact

Drum Packing Palletized Drum Packing Palletized & Shrink Wrapped. 25 50kg HDPE Laminated Bags. Exports to USA UAE Europe Tanzania Kenya Egypt Turkey Brazil Chile Argentina Dubai Jumbo Packing Propionic Acid Suppliers

Propionic Acid FCC Food SDS GHS MSDS of Manufacturers, Propanate Food Grade

CAS Number: 79-09-4, EINECS EC Number:201-176-3 , Molecular Formula:CH3CH2COOH, Molecular Weight:74.08

Specifications Propionic Acid Manufacturers

Propionic Acid SDS, Safety Data Sheet
MSDS, Material Safety Data Sheet

Section 1 - Chemical Product and Company Identification

Product Name & Other Names: Propionic Acid or Propanoic acid or Propanyl acid or Acid C3.
CAS#: 79-09-4
EINECS EC Number: 201-176-3
Molecular Formula: 
C3H6O2
Molecular Weight: 
74,08
Relevant uses and uses advised against (if any)
: Industrial Manufacturing.

Section 2 - Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008

Flammable liquids Category 3, H226
Skin corrosion Category 1B, H314
Specific target organ toxicity - single exposure Category 3, Respiratory system, H335

Labeling according to GHS & Regulation (EC) No 1272/2008

GHS Label Elements
Flammable
Flammable

GHS Label Elements
Corrosive
Corrosive

Signal Words: Danger

Hazard statements:
H226: Flammable liquid and vapor.
H314: Causes severe skin burns and eye damage.
H335: May cause respiratory irritation.

Precautionary statements:
P210: Keep away from heat, sparks, open flames, hot surfaces. - No smoking.
P233: Keep container tightly closed.
P240: Ground/bond container and receiving equipment.
P241: Use explosion-proof electrical, ventilating, lighting equipment.
P242 - Use only non-sparking tools.
P243: Take precautionary measures against static discharge.
P260: Do not breathe mist, vapors, spray.
P264: Wash exposed skin thoroughly after handling.
P280: Wear protective clothing, protective gloves, eye protection, face protection.
P301+P330+P331: IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
P303+P361+P353: IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P304+P340: IF INHALED: remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305+P351+P338: If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a POISON CENTER or doctor/physician.
P314: Get Medical advice/attention if you feel unwell.
P337+ P313: If eye irritation persists: Get medical advice/ attention.
P360: Rinse immediately contaminated clothing and skin with plenty of water before removing clothes.
P363: Wash contaminated clothing before reuse.
P370+P378: In case of fire: Use carbon dioxide (CO2), powder, alcohol-resistant foam for extinction.
P403+P235: Store in a well-ventilated place. Keep cool.
P405: Store locked up.
P501: Dispose of contents/container to comply with local, state, and federal regulations.

Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbols:
F Flammable
C Corrosive
Risk Phrases:
R10 = Flammable.
R34 = Causes burns.
R37 = Irritating to respiratory system.
R41 Risk of serious damage to eyes.

Section 3 - Composition/Information on Ingredients

Product Name & Other Names: Propionic Acid or Propanoic acid or Propanyl acid or Acid C3.
CAS#: 79-09-4
EINECS EC Number: 201-176-3
Percent
: 99-100% on dry basis. Dilution is always with water.

Section 4 - First Aid Measures

Always consult a physician after the first aid is given.

Eyes: Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid. Do NOT allow victim to rub or keep eyes closed.
Skin: Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Get medical aid if irritation develops or persists. Wash clothing before reuse.
Ingestion: Do NOT induce vomiting. If victim is conscious and alert, give 2-4 cupful of milk or water. Never give anything by mouth to an unconscious person. Get medical aid.
Inhalation: Remove from exposure to fresh air immediately. If breathing is difficult, give oxygen. Get medical aid. Do NOT use mouth-to-mouth resuscitation. If breathing has ceased apply artificial respiration using oxygen and a suitable mechanical device such as a bag and a mask.

Section 5 - Fire Fighting Measures

General Information: As in any fire, wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion.
Flammable Limits: LOWER: 2.9% UPPER: 12.1%
Flash Point: 52C - 54C / 126F - 130F (closed cup)
Auto Ignition Temperature: 485C / 905F
Extinguishing Media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Cool containing vessels with water jet to prevent pressure build-up, auto-ignition, or explosion. EMITS TOXIC FUMES UNDER FIRE CONDITIONS.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used.

Section 6 - Accidental Release Measures

Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Ensure adequate ventilation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment Cleanup procedures and Storage: Contain spilled material. Use proper personal protective equipment. Restrict unprotected personnel from the area. Remove all ignition sources and ventilate area. Contain the spill with sand or other inert absorbent material, neutralize with sodium bicarbonate or calcium hydroxide, and deposit in a sealed bag or container. Use water spray to dilute spill to a non-flammable mixture. Use water spray to disperse the gas/vapor. Remove all sources of ignition. Use a spark-proof tool. Provide ventilation. Cover with material such as dry soda ash or calcium carbonate and place into a closed container for disposal.

Section 7 - Handling and Storage

Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Do not leave the material container open. Store protected from heat, sparks and ignition sources and incompatible materials. Do not store with incompatible materials like oxidizing agents, strong alkalis, and metals.

Section 8 - Exposure Controls, Personal Protection

Airborne Exposure Limits: Airborne Exposure Limits:
ACGIH Threshold Limit Value (TLV): 10 ppm (TWA)
OSHA PEL 10ppm / 30mg/m 3
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator (NIOSH type N95 or better filters) may be worn. If oil particles (e.g. lubricants, cutting fluids, glycerin, etc.) are present, use a NIOSH type R or P filter. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area of Propionic acid.
Other Control Measures: Maintain good housekeeping in work area.

Section 9 - Physical and Chemical Properties

Appearance: Clear Liquid
Odor: Rancid
Odor threshold: Not available.
pH: 2-3 for 1% solution, 2.4 (1.0M solution)
Relative density: 0.993
Boiling Point: 141C (244.5F)
Melting Point:
 -20.8C (-6F)
Flash Point: 52C - 54C / 126F - 130F (closed cup)
Auto Ignition Temperature: 485C / 905F
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: Soluble in water
Viscosity: Not available.

Section 10 - Stability and Reactivity

Chemical Stability: Propionic acid is stable under normal temperatures and pressures.
Conditions to Avoid: Incompatible materials, exposure to heat, spark.
Incompatibilities with Other Materials: Oxidizing agents, strong alkalis and metals.
Hazardous Decomposition Products: Carbon monoxide, irritating and toxic fumes and gases, carbon dioxide.
Hazardous Polymerization: Will not occur.

Section 11 - Toxicological Information

LD50 Oral - Rat - male and female - 3.455,1 mg/kg
LC50 Inhalation - Rat - male and female - 4 h - > 20 mg/l
LD50 Dermal - Rat - female - 3.235 mg/kg
LD50 Intravenous - Mouse - 625 mg/kg
LD50 Parenteral - Rat - 3.500 mg/kg
Carcinogenic Effects: Not a reported carcinogen by IARC, NTP, ACGIH, OSHA.
Mutagenic Effects: Not available.
Developmental Toxicity: Not available.
Reproductive Effects: No information available.

Section 12 - Ecological Information

Acute toxicity:
Fish: LC-50 (golden orfe, 96 h): > 1,000 mg/l
Aquatic invertebrates: EC-50 (Water Flea, 48 h): > 500 mg/l
Toxicity to Aquatic Plants: EC-50 (Scenedesmus subspicatus, 72 h): > 500 mg/l
Results of PBT and vPvB assessment: This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

Section 13 - Disposal Considerations

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container of Propionic acid and unused contents in accordance with local requirements. Follow all Pollution control rules.

Section 14 - Transport Information

DOT USA, TDG Canada & ADR/RID Europe
UN number: 3463
Class: 8 (3); Packing group: II
IMDG/IMO
UN number: 3463
Class: 8 (3); Packing group: II
IATA/ICAO
UN number: 3463
Class: 8 (3); Packing group: II

Section 15 - Regulatory Information

USA:
SARA 311/312 Hazards: See section 2.

Section 16 - Additional Information

European Labeling in Accordance with EC Directives:
H226: Flammable liquid and vapor.
H314: Causes severe skin burns and eye damage.
H335: May cause respiratory irritation.

Disclaimer:
****************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This Propionic Acid SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
****************************

Propionic Acid FCC Food USP NF Grade Manufacturers:

Anmol Chemicals
S-8, SARIFA MANSION, 2ND FLANK ROAD, CHINCHBUNDER, MUMBAI 400009, INDIA
TEL: (OFFICE) 91-22-23770100, 23726950, 23774610, 23723564. FAX: 91-22-23728264

e-mail: anmolc@mtnl.net.in

Anmol Chemicals

Exports to USA, Canada, UAE, Dubai, South Africa, Tanzania, Kenya, Nigeria, Egypt, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Europe Netherlands, Italy, Spain, Germany, Portugal, France, Malaysia, Indonesia, Thailand, Vietnam, Korea, Japan, etc.

Copyright and Usual Disclaimer is Applicable. 14 January, 2022